Ajinkya Electronic Systems
Ajinkya Electronic Systems
Mahim, Mumbai, Maharashtra
Send E-mail
Send SMS
Home  » We Manufacture  » 

Process Loggers


Backed by a rich industry experience, we are able to offer a wide range of Process Loggers to our clients. There are various process parameters which are to be logged / recorded against time in various industries. These can be physical parameters, such as temperature, flow, pressure, humidity, level or electrical parameters, such as AC / DC voltages, currents, power parameters.

REQUEST CALLBACK
Ask for Price

The IM 1910 Series Flow Loggers offered by us are micro controller based digital and highly versatile loggers. These can work with external flow sensors offering either electrical output like 4-20mA or 0-10 V or pulses and are used for measuring flow of different kinds of liquids, such as water, diesel & oils.

We offer flow sensors of PD (Positive Displacement) type and Turbine type that can be used along with these flow meters. These sensors are available from sizes 1” to 4” (15NB to 100NB) and are ideal for free flowing liquids without any sediment.


Specifications:

  • The intrusive type of sensors and fit on pipe lines with end flanges
  • Material of construction can be aluminum, brass, MS, SS304 or SS316 with delrin rotors depending on suitability for the liquid
  • Flow loggers derive the flow rate as well as total flow values from the input signal and record them against time
  • They can be thus used as flow totalisers as well
  • With addition of set point, they can control the flow amount to be dispensed

Options available:

  • Display: 7 segment LED display / Alphanumeric LCD display
  • Inputs: 4-20mA / Pulses / Unbalance Bridge / 0-10 mV / 100 mV
  • Memory: 32k / 64k / 2MB / USB Flash etc
  • Connectivity: RS232 / USB / RS485 / Ethernet TCP/IP etc
  • Protocol: Modbus / Text / Direct Centronics Printer
  • Options: Serial Printer / Alarm Relay / Retransmission 4-20mA
  • Alarm: High/ Low / Very High / Very Low
  • Log Interval: Minute. Seconds / Hours. Minutes
  • Supply: AC Mains operated / DC Operated / Battery Operated
  • Enclosure: Panel Mount / DIN Size / Wall mount / Table Top


Additional Information:
  • Item Code: IM1910

Yes! I am Interested


REQUEST CALLBACK
Ask for Price

Our organization deals in offering IM2000 Pressure Loggers that accepts input from various types of pressure sensors, load cells, torque sensors and strain gauges. These can be used as pressure logger or load logger or strain gauge logger, which give output signal either in 4-20mA form or resistive bridge form.


Options available:

  • Display: 7 segment LED display / Alphanumeric LCD display / Graphic LCD display
  • Sensor Inputs: 4-20 mA / load cell / Wheatstone bridge / load cell
  • Number of channels: 1/ 2/4/8
  • Memory: 32k / 64k / 2MB / USB Flash
  • Connectivity: RS232 / USB / RS485 / Ethernet TCP/IP etc
  • Protocol: Modbus / Text
  • Options: SMS alarm / Centronics Printer interface / Grouping of channels
  • Log Interval: Minute. Seconds / Hours.Minutes
  • Alarm: High/ Low / Very High / Very Low / Common relay/ Two relays/ Individual Channel Relays
  • Supply: AC Mains operated / DC Operated
  • Enclosure: Panel Mount / DIN Size / Wall mount / Table Top / Flameproof

Yes! I am Interested


REQUEST CALLBACK
Ask for Price

Our range of Level Logger can take signal from external level sensors and record these values in memory. There are various methods for recording the level and they can be using level sensor, pressure sensor or load cell. In level sensors there are different types like resistance sensor, Doppler effect Radar sensors, Ultrasonic sensors. Our loggers can accept inputs from either of these sensors and derive the level value based on sensor signal input.

 

 Options available:
  • Display: 7 segment LED display / Alphanumeric LCD display
  • Inputs: 4-20mA / Resistance / 0-10V / 0-100 mV / 0-20mA
  • Memory: 32k / 64k / 2MB / USB Flash etc
  • Connectivity: RS232 / USB / RS485 / Ethernet TCP/IP etc
  • Protocol: Modbus / Text
  • Options: Serial Printer / Alarm Relay / Retransmission 4-20mA
  • Alarm: High/ Low / Very High / Very Low
  • Log Interval: Minute. Seconds / Hours. Minutes
  • Supply: AC Mains operated / DC Operated
  • Enclosure: Panel Mount / DIN Size / Wall mount / Table Top / Flameproof

Yes! I am Interested


REQUEST CALLBACK
Ask for Price

Besides from physical parameters; application also demands logging of voltages and currents. The IM2000 series Voltage Logger / Current Logger / Power Logger offered by us can accept DC shunt inputs, signals from convertors 4-20mA range or CT current inputs for higher AC currents or AC signals from PT. These can calculate values from the recorded channels to generate additional channel values.

 

Options available:


  • Display: 7 segment LED display / Alphanumeric LCD display / Graphic LCD display
  • Inputs: DC voltage / 0-75mV DC Shunt input / AC Voltage / AC current from CT
  • Number of channels: 1/ 2/4/8
  • Memory: 32k / 64k / 2MB / USB Flash etc
  • Connectivity : RS232 / USB / RS485 / Ethernet TCP/IP etc
  • Protocol: Modbus / Text etc.
  • Options: SMS alarm / Centronics Printer interface
  • Log Interval: Minute. Seconds / Hours. Minutes
  • Supply: AC Mains operated / DC Operated
  • Enclosure: Panel Mount / DIN Size / Wall mount / Table Top

Yes! I am Interested


 






Corporate Brochure



X

 

 

Send SMS
Ajinkya Electronic Systems
Rajesh Doshi  (Managing Partner)
No. 131, Kakad Industrial Estate Off L. J. Cross Road No. 3, Mahim [West]
Mumbai - 400016 , Maharashtra , India
Send E-mail