| Home | About Us | We Manufacture | Media Gallery | Client Commendations | Happenings | Contact Us | Enquiry |
![]()
![]()
| We offer a comprehensive range of Control & Automation Products including electronic automation products, control automation products, that have been widely appreciated for its outstanding performance and precise calibration. We make use of optimum quality material and latest technology to manufacture our gamut. These products can further be customized as per the specifications developed by the clients. The entire range includes of data logger, flow ratemeters, multichannel temperature controllers, ramp soak controllers, profile controllers, temperature controllers, profile generators, level controllers, digital timer, digital counters, temperature humidity controller. |
|
We offer a wide range of data logger that covers extensively to meet the diverse requirements for various industrial applications. The Loggers are available in DIN Standard size of 96 x 192 mm are ideally designed for logging physical parameters such as temperature, pressure and flow. Data Loggers can be connected to a standard printer straight away to create reports directly also without using of PC. Logger can be used online and offline and compatible with WIN 98 graphic data logging software and also attuned with Elipse Windows SCADA software. In all the new product fault recorer is available for logging of machine on / off timings. Features
|
IM 1900 Series Indicators are microcontroller based, digital and highly veratile indicator series. Flow ratemeters or totalisers are for measuring flow of liquid or gas. Different models are available to accept inputs as
Thus it can be interfaced to wide range of sensors. Various options as Alarm relay outputs, Retransmission of signal, set point etc. are available. Features
Specifications
|
|
|
We manufacture wide range of universal input / dedicated input multichannel temperature controllers that serve the diverse requirements of various industries. These controllers receive inputs from different sensors and the type of sensor is field selected. Controllers are available as On / Off type, Proportional and PI type. Available upto 16 inputs in universal type multiple channel controllers also have 48 channels for dedicated type in single package. Features
|
Profile Controller is Process Controller for controlling process parameter against time. User can define the profile he wants with the help of extensive instruction set. Unit supports instructions like jump, loop, loop with count apart from ramp and soak control. Auxiliary relays are provided which can be used to operate external controls like valve or hooter etc. Features
|
|
|
Ajinkya temperature controllers are Microcontroller based highly versatile controllers available with control algorithm as On / Off, Proportional, PI or PID to choose from depending on process requirement. Control parameters are user configurable on site. Various options like independent Heat / Cool relay output, input from sources like Rtd, Thermocouple or 4-20 mA etc are available. Other versions of temperature controllers are also available as
|
Profile generator generates voltage / current signal output against time. The waveform / pattern to be generated is user programmable. Features
Specifications Output:4-20 mA / 0-10 V Time range:1 minute to 99 hours 59 minutes Number of steps: 10 / 24 / 100 Number of programmes: Upto 100 Supply: 230 V AC / 110 V AC / 24 V DC / 12 V DC Size:96 x 96 mm depth 150 mm Options
|
|
|
Display : 4 / 6 digit Single / Dual Settings : Membrane Keyboard Ranges : Various from 0.01 sec to 9999 hrs. Resolution : Minimum 1 mSec possible Count mode : Up / Down Output : Upto 4 Relays. More relays possible externally. Battery Backup : Optional Other Options : RS232 / Modbus Connectivity |
Another application for event loggers is for production monitoring. It is an effective tool in the hands of management. Management can observe when a particular machine was switched on, when it was idle, when there was no power. Information about run time, idle time etc can be derived from the logs in the event logger.
In the simplest form the event logger can generate a report of at what time a particular system was switched on and at what time it was switched off. Typical report can be.
Number of such units can be networked on an RS485 bus and connected to PC. Ajinkya provides Production monitoring software which can upload data from these units and generate shift wise reports.
|
|
|
Data Loggers are electronic instruments which capture and record data related to physical parameters like temperature, humidity, pressure, liquid flow etc. as well as electrical parameters like voltage, current etc. and reproduce them in a form suitable to the user. The reading of information, storage and reproducibility are the important parameters that define a data logger. Depending on how each of these parameters are handled data loggers can be classified in various categories and have various nomenclatures. Here are the various parameters that user can select from to choose a data logger
Display : 7 segment LED display / Alphanumeric LCD display / Graphic LCD display Sensor Inputs : RTD / Thermocouple / mV / mA / load cell / Universal etc. Number of channels : 1/ 2/4/8/16/32 etc. Memory : 32k / 64k / 2MB / USB Flash etc Connectivity : RS232 / USB / RS485 / Ethernet TCP/IP etc Protocol : Mod bus / Text etc. Options : SMS alarm / Centronics Printer interface / Grouping of channels etc Log interval : Minute. Seconds / Hours.Minutes etc Alarm : High/ Low / Very High / Very Low / Common relay/ Two relays/ Individual Channel Relays Supply : Battery Operated / AC Mains operated / DC Operated Enclosure : Panel Mount / DIN Size / Wall mount / Hand held / Table Top / Flameproof |
Mr. Rajesh Doshi
(Manager)
No. 131, Kakad Industrial Estate, Off L. J. Cross Road No. 3, Mahim
Mumbai,
Maharashtra -
400 016,
India
Telephone: +(91)-(22)-24312031
© Ajinkya Electronic Systems, All Rights Reserved. (Terms of Use)
Developed and Managed by