Ajinkya Electronic SystemsAjinkya Electronic Systems

Home About Us Contact Us Enquiry We Manufacture

Control and Automation Products

We offer a comprehensive range of Control & Automation Products including electronic automation products, control automation products, that have been widely appreciated for its outstanding performance and precise calibration. We make use of optimum quality material and latest technology to manufacture our gamut. These products can further be customized as per the specifications developed by the clients. The entire range includes of data logger, flow ratemeters, multichannel temperature controllers, ramp soak controllers, profile controllers, temperature controllers, profile generators, level controllers, digital timer, digital counters, temperature humidity controller.
Share: FacebookTwitterGoogle Buzz

Data Logger

Data Logger 

We offer a wide range of data logger that covers extensively to meet the diverse requirements for various industrial applications. The Loggers are available in DIN Standard size of 96 x 192 mm are ideally designed for logging physical parameters such as temperature, pressure and flow.

Data Loggers can be connected to a standard printer straight away to create reports directly also without using of PC.

Logger can be used online and offline and compatible with WIN 98 graphic data logging software and also attuned with Elipse Windows SCADA software.
In all the new product fault recorer is available for logging of machine on / off timings.

Features
  • 4 digit x 3 row LED display
  • Dust proof membrane keypad
  • Microcontroller based Digital Circuitry
  • Centronics Parallel printer interface
  • 80 Column / 24 Column Printer Report selection.
  • On line / Off line logging
  • Individual Channel enable / disable facility.
  • Individual Channel High / Low Alarm
  • For alarm one relay output
  • Real time clock.
  • Print interval programmable in hours and minutes.
  • Scan interval programmable in seconds
  • 6 Digit Batch number programmable.
  • RS-232 Output optional for PC Interface.
  • 32 k RAM with internal rechargeable NiCd battery back up.
  • Size 96(W) x 192(H) x 150(D) mm.
  • 8 / 16/ 24 Analog Channels for thermocouple/RTD Pt100/4-20 mA/0-10 V inputs. (Factory Set).

Send Enquiry

Flow Rate Meters 

IM 1900 Series Indicators are microcontroller based, digital and highly veratile indicator series. Flow ratemeters or totalisers are for measuring flow of liquid or gas. Different models are available to accept inputs as

  • 4-20 mA signal
  • Pulses
  • Unbalance bridge inputs
  • 0-10 / 100 mV etc.

Thus it can be interfaced to wide range of sensors. Various options as Alarm relay outputs, Retransmission of signal, set point etc. are available.

Features

  • Microcontroller based highly versatile and reliable digital circuitry.
  • Dust proof membrane keyboard for programming.
  • Input from - Pulses - 4-20 mA / 0-10 mA / 0-100 mV - Unbalance bridge
  • Different models with Four digit display / Six digit display / Independent display for Totaliser etc. are available.
  • One relay output with preset
  • Option of 4-20 mA signal output corresponding to flow.
  • Selectable decimal point for flow.
External Reset input to reset totaliser count.

Specifications

  • Input: -5-12 V / Potential free pulse -4-20 mA / 0-10 mA / 0-100 mV factory set -Unbalanced bridge
  • Displays -0.5 inch 4 digit / 6 digit or -4 + 6 digit
  • Relay output:230 V / 5A (resi) Supply: 230 V / 110 V AC or 24 V DC Size: 96 x 96 x 100 / 150 mm. �
Flow Rate Meters

Send Enquiry

Multichannel Temperature Controllers

Multichannel Temperature Controllers 

We manufacture wide range of universal input / dedicated input multichannel temperature controllers that serve the diverse requirements of various industries. These controllers receive inputs from different sensors and the type of sensor is field selected. Controllers are available as On / Off type, Proportional and PI type.
Available upto 16 inputs in universal type multiple channel controllers also have 48 channels for dedicated type in single package.
Features
  • Microcontroller based Digital Circuit
  • Dust proof membrane keypad
  • 4 digit x 2 row LED display
  • 8 / 16 / 32 / 36 / 40 / 48 Inputs for RTD / thermocouple
  • High and Low alarm outputs with limits programmable
  • Control algorithm On/Off, P or PI with programmable control parameter
  • Data Logging function optional with Centronics Parallel printer interface
    Or RS232 / RS485 Serial interface
  • 8 / 16 analog channels for thermocouple Type J, K, R or T / RTD Pt100 / 4-20 mA field selectable

Specifications
  • Resolution: 0.1 C for RTD
  • Input thermocouple type J, K, R, T, S / RTD Pt100 / 4-20 mA,
    0-100 mV field selectable.
  • 1 C for thermocouple
  • 1 C +/- 1 C for thermocouple
  • Accuracy: 0.1 C / 0.2 C +/- 1 digit (range 199.9 / 399.9)
  • Outputs: Open Collector
  • Options: Data Logging
  • Centronics Parallel printer output
  • RS232 / RS485 Serial Modbus Interface
  • Size: 96 x 96 x 150 mm. (DIN standard)
  • Supply: 230 V AC / 110 V AC / 12 V DC / 24 V DC.

Send Enquiry

Ramp Soak Controllers 

Ramp soak controllers control the rate of rise (ramp) of temperature / controlled parameter and then maintain it to the programmed value for programmed time (soak). Ramp down is available as an option.

Features
  • Microcontroller based circuitary
  • Dual display for setpoint and current temperature
  • Dust proof membrane keypad for programming
  • Rate of rise of temperature programmable
  • Soaking time interval programmable
  • Ramp down rate programmable (Optional)
  • Heating and cooling (Optional) outputs
  • PID Control algorithm
  • Data logging Option
  • On line data printing with serial printer option

Specifications

Input: RTD Pt100 / Thermocouple / 4-20 mA Range:Linearised Output:Relay / SSR Compatible / 4-20 mA / 0-10 V
Ambient compensation: Built in Accuracy 0.1 C / 0.2 C +/- 1 digit (range 199.9 / 399.9) 1 C +/- 1 C for thermocouple Supply: 230 V AC / 110 V AC / 24 V DC Size: 96 x 96 mm depth 150 mm

Options
  • Cooling output
  • Ramp down setting
  • Real time clock
  • RS232 Data output
  • Modbus interface
  • Data Logging

Models

  • IM2755 : Ramp soak controller

Prefix

  • T - Serial RS232 Text mode
  • S - Serial RS232 Modbus
  • M - Serial RS485 modbus
  • C - 4-20 mA output
  • O - SSR compatible output
  • D - Delayed output �
Ramp Soak Controllers

Send Enquiry

Profile Controllers

Profile Controllers 

Profile Controller is Process Controller for controlling process parameter against time.

User can define the profile he wants with the help of extensive instruction set. Unit supports instructions like jump, loop, loop with count apart from ramp and soak control.

Auxiliary relays are provided which can be used to operate external controls like valve or hooter etc.
Features
  • Microcontroller based Digital Circuitry
  • Four digit LED display for parameter indication.
  • Six digit display for programming and showing setpoint values.
  • Dust proof membrane keypad for programming.
  • 100 Programs of 16 steps each
  • Input interface : Pt 100 or Thermocouple or 4 t0 20 mA as per the requirement.
  • Control algorithm On/Off, P , PI or PID with programmable control constants.
  • Step change over temperature band programmable.
  • Programming instructions like Jump, loop, loop with count, etc. supported.
  • NV RAM storage to retain setpoint in case of power failure.
  • Upto 2 Auxilliary relay contacts possible
  • Independent Heat and Cool relay outputs optional.
  • 4-20 mA or 0-10 V Control output optional.

Send Enquiry

Temperature Controllers 

Ajinkya temperature controllers are Microcontroller based highly versatile controllers available with control algorithm as On / Off, Proportional, PI or PID to choose from depending on process requirement. Control parameters are user configurable on site.

Various options like independent Heat / Cool relay output, input from sources like Rtd, Thermocouple or 4-20 mA etc are available.

Other versions of temperature controllers are also available as

  • Profile Controller : To control temperature against time. E.g. Ramp Soak Control
  • Temperature Humidity Controller
  • Multi setpoint Temperature Controller
  • Multi channel temperature controllers : multiple temperature controllers in a single package. Upto 48 channels.

Features

  • Microcontroller based Digital Circuitry
  • Four digit LED display for parameter indication and 4 digit for setpoint indication.
  • Dust proof membrane keypad for programming.
  • Input interface : Pt 100 or Thermocouple or 4 t0 20 mA as per the requirement.
  • Control algorithm On/Off, P , PI or PID with programmable control constants.
  • NV RAM storage to retain setpoint in case of power failure.
  • Control output Relay outputs rated 230V / 5A (resistive) or 4-20 mA
  • Independent Heat and Cool relay outputs optional.
  • High Low relay alarm outputs optional.
  • 4-20 mA or 0-10 V Control output optional.
  • RS 232 Serial Interface for PC or Serial Printer (Optional)
Temperature Controllers

Send Enquiry

Profile Generators

Profile Generators 

Profile generator generates voltage / current signal output against time. The waveform / pattern to be generated is user programmable.

Features
  • Microcontroller based digital circuitary
  • Dust proof membrane keypad
  • 16 programmes of 100 steps (Optional)
  • RS232 / 485 PC connectivity

Specifications
Output:4-20 mA / 0-10 V
Time range:1 minute to 99 hours 59 minutes
Number of steps: 10 / 24 / 100
Number of programmes: Upto 100
Supply: 230 V AC / 110 V AC / 24 V DC / 12 V DC
Size:96 x 96 mm depth 150 mm

Options
  • RS232 / RS485 Modbus interface
  • Serial Printer Interface
  • Data Logging
  • Voltage signal input

Send Enquiry

Water Level Controllers 

Our series of water level controllers serves for various industrial applications where pump is required. It is used for switching on and off when the overhead water tank is full or when it is empty.

Features
  • Plastic molded magnetic sensors optional
  • Contact inputs for sensors are potential free
  • For sensor status LED indications is given
  • Compact wall mount unit
  • Relay output to switch pump / solenoid valve on off
Water Level Controllers

Send Enquiry

Digital / Cyclic Timer

Digital / Cyclic Timer 

Display : 4 / 6 digit Single / Dual
Settings : Membrane Keyboard
Ranges : Various from 0.01 sec to 9999 hrs.
Resolution : Minimum 1 mSec possible
Count mode : Up / Down
Output : Upto 4 Relays. More relays possible externally.
Battery Backup : Optional
Other Options : RS232 / Modbus Connectivity

Send Enquiry

Digital Counters 

A digital counter, or simply counter, is a semiconductor device that is used for counting the number of times that a digital event has occurred. The counter's output is indexed by one LSB every time the counter is clocked.

Display:
4 / 6 digit Single / Dual
Settings: Membrane Keyboard
Count mode : Up / Down
Input : Proximity / Potential free Contacts
Output : Upto 3 Relays. More relays possible.
Battery Backup : Optional Optical Encoder / Quaderature Prescaling : Optional. Multiplying / dividing constant programmable
Reset : External Manual / Auto / Programmable timeOther Options: External Start / Stop / RS232 / Modbus Connectivity


  • Preset Counter
  • Sequential Counter
  • Counter with Totaliser
  • Batch Counter
  • Vending Machine Timer / Counters
  • Up Down Counters / Prescaling Counters
Digital Counters

Send Enquiry

Temperature Humidity Controller

Temperature Humidity Controller 

IM3700 series temperature humidity controllers are micro controller based highly versatile controllers for combined control of temperature and humidity. Controller is available with PID control algorithm. Control parameters are user configurable on site. Controllers are available which can accept input from different type of humidity sensors as well as RTD sensor for dry bulb / wet bulb measurement techniques. Useful in pharmaceutical industry, environment chambers, green house rooms etc.

Features
  • Microcontroller based Digital Circuitry
  • Two Row Four digit LED display for parameter indication.
  • Dust proof membrane keypad for programming.
  • Input interface: Pt 100 RTD for temperature.
  • RTD for Dry / Wet bulb technique.
  • 4-20 mA from Humidity sensor
  • 0-10 V or 0-3 V from Humidity sensor.(Factory set).
  • Control algorithm independent PID
  • NV RAM storage to retain set point in case of power failure.
  • Control output: Relay outputs rated 230V / 5A (resistive).
  • RS 232 Serial Interface for PC or Serial Printer (Optional).
  • Real time Clock (Optional).

Send Enquiry

Production Monitor 

Another application for event loggers is for production monitoring. It is an effective tool in the hands of management. Management can observe when a particular machine was switched on, when it was idle, when there was no power. Information about run time, idle time etc can be derived from the logs in the event logger.

 

In the simplest form the event logger can generate a report of at what time a particular system was switched on and at what time it was switched off. Typical report can be

 


Number of such units can be networked on an RS485 bus and connected to PC. Ajinkya provides Production monitoring software which can upload data from these units and generate shift wise reports.

Production Monitor

Send Enquiry

Data Logger

Data Logger 

Data Loggers are electronic instruments which capture and record data related to physical parameters like temperature, humidity, pressure, liquid flow etc. as well as electrical parameters like voltage, current etc. and reproduce them in a form suitable to the user. The reading of information, storage and reproducibility are the important parameters that define a data logger.

Depending on how each of these parameters are handled data loggers can be classified in various categories and have various nomenclatures.

Here are the various parameters that user can select from to choose a data logger

 

Display : 7 segment LED display / Alphanumeric LCD display / Graphic LCD display

Sensor Inputs :  RTD / Thermocouple / mV / mA / load cell / Universal etc.

Number of channels : 1/ 2/4/8/16/32 etc.

Memory : 32k / 64k / 2MB / USB Flash etc

Connectivity : RS232 / USB / RS485 / Ethernet TCP/IP etc

Protocol : Modbus / Text  etc.

Options :  SMS alarm / Centronics Printer interface / Grouping of channels etc

Log interval : Minute. Seconds / Hours.Minutes etc

Alarm : High/ Low / Very High / Very Low / Common relay/ Two relays/ Individual Channel Relays

Supply : Battery Operated / AC Mains operated / DC Operated

Enclosure : Panel Mount / DIN Size / Wall mount / Hand held / Table Top / Flameproof

Send Enquiry

Humidity Controller 

IM3700 Series Temperature Humidity controllers are Microcontroller based highly versatile controllers for combined control of Temperature and Humidity. Controller is available with PID control algorithm. Control parameters are user configurable on site. Controllers are available which can accept input from different type of Humidity sensors as well as RTD sensor for Dry Bulb / Wet Bulb measurement technique.Useful in pharmaceutical industry, environment chambers, green house rooms etc. Features • Microcontroller based Digital Circuitry • Two Row Four digit LED display for parameter indication. • Dust proof membrane keypad for programming. • Input interface : Pt 100 RTD for temperature. RTD for Dry / Wet bulb technique. or 4-20 mA from Humidity sensor or 0-10 V or 0-3 V from Humidity sensor. (Factory set). • Control algorithm independent PID • NV RAM storage to retain setpoint in case of power failure. • Control output : Relay outputs rated 230V / 5A (resistive) or Open Collector Outputs. High Low setpoint with Relay output for Compressor control. • RS 232 Serial Interface for PC or Serial Printer (Optional). • Real time Clock (Optional).
Humidity Controller

Send Enquiry

Profile Controller

Profile Controller 

Profile Controller is Process Controller for controlling process parameter against time.

User can define the profile he wants with the help of extensive instruction set. Unit supports instructions like jump, loop, loop with count apart from ramp and soak control.

Auxiliary relays are provided which can be used to operate external controls like valve or hooter etc. Relay On and Off instructions are supported.

Unit is available with control algorithm as On / Off, Proportional, PI or PID to choose from depending on process requirement.

Send Enquiry

Showcase

View all our products / services as a slide show.

Play Now

New Development for Automobile Industry
Ajinkya Electronic Systems Developed A New Device for Automobile Industries....

read more.. view all..

Hot Offers

Data Logger

Data Logger

Water Level Controllers

Water Level Controllers

Ampere Hour Meters

Ampere Hour Meters

Siren Controller

Siren Controller



Contact us

Mr. Rajesh Doshi
131, Kakad Industrial Estate Off,, L. J. Cross Road No. 3, Mahim
Mumbai, Maharashtra - 400 016, India
Telephone:  +(91)-(22)-24312031

Contact via E-mail

Contact via Mobile

Contact via SMS

Home | About Us | Company Video | We Manufacture | Happenings | Client Commendations | Site Map | Contact Us | Enquiry

Member IndiaMART.com© Ajinkya Electronic Systems, All Rights Reserved. (Terms of Use)
Developed and Managed by IndiaMART InterMESH Limited